Using 'quickscans', Factor4 maps your building portfolio.

Factor4 carries out scans of buildings for organisations that own a property portfolio and want a quick overview of the condition and energy efficiency of their buildings.

A Portfolio Scan consists of a short visit to each building, during which the inspector uses scorecards to assess a number of aspects relating to 3 themes: the current state of the building (condition), ease of maintenance, and the energy efficiency of the building envelope and the installations. Finally, the Quickscan also estimates how future-proof the building is.

The methodology and the scorecards are based on:

  • the Dutch standard NEN 8021: Assessment of the performance in use of non-residential buildings

  • the Dutch standard NEN 2767: Condition assessment of buildings, the methodology

  • the Flemish sustainability meter GRO: Towards future-oriented construction projects

The report presents the overall conclusions of the Portfolio Scan and a first analysis of the results, and also summarises the detailed approach and the underlying information.

The overall conclusions of a Portfolio Scan give an overview of the buildings' scores. The maximum score is 4 (good), the minimum score is 1 (poor).

During the site visit, the inspector gives each sub-aspect a score of 1 (poor), 2 or 3 (moderate) or 4 (good). These scores can be described as follows:

The Portfolio Scans provide a quick and easy overall picture of the condition of the building portfolio. The results and insights from the Quickscan can help to

  • set priorities for urgent measures needed in the buildings to bring the portfolio up to standard,

  • draw up a well-founded strategic real estate plan and define a core portfolio that takes into account how future-proof the buildings are,

  • identify natural renovation moments in the various buildings that can be used to carry out a deep energy renovation.

A Portfolio Scan also examines how future-proof the portfolio is. From a structural point of view, a building's future-proofness relates to how easily it can be adapted to changing functions (changing programmes of requirements). In other words, the key question here is: does the structure of the building allow alterations to accommodate a different function?

Some concrete parameters that make this evaluation possible are:

  • Is the clear height sufficient to install any new building services, e.g. ventilation?

  • Does the load-bearing structure consist of columns and beams with large spans, or rather of load-bearing interior walls?

  • Are there expansion options for the volume (vertical and/or horizontal)?

  • Is there sufficient space for the safe circulation of people (vertical and horizontal)?

Interested, or would you like more information? Please don't hesitate to contact us!